PowerEdge 2650 ESM4 error (Embedded Server Management)

PE2650 motherboardThis is the review of the PowerEdge 2650 ESM error that people are experiencing and having  a big trouble due this error. Server hang at startup and a manual interruption required to boot the server (At startup system says to press F1 for normal boot and F2 to enter in setup program). Server cooling fans always kept running and become annoying due to a loud noisy environment. Sometimes server behave abnormally and restart without any intimation or hang without any specific reason. This happens due to various problem with the Embedded Server Management module.

poweredge2650 esm4 card

This module is installed in the server to enhance the capability and install some extra PCI devices. Its a little blur picture but you can see this if you can open the chassis of your server.

PowerEdge 2650 ESM (embedded Server Management) error can be corrected by doing a very simple task given below;

Remote Access Controller (RAC) Firmware Repair Utility

Firmware Version 3.13 and Firmware Version 3.35

Instructions to create Repair Diskettes:
—————————————————————————–
1. This utility will require 2 formatted diskettes.
2. Insert the first diskette
3. Press the Continue button.
4. When the copy is complete, remove the diskette and insert the second diskette.
5. Press the Continue button.
6. When copy is complete, press the Finish button.

RAC Controllers Supported:
Embedded Remote Access [ERA]
Remote Access Card III/XT

RAC Repair Utility Instructions:

1. Insert the first update diskette into the target system with RAC installed  and reboot the system.

You are prompted to confirm reflashing the RAC.

2. After you confirm the update, you are prompted to insert the second update diskette.

The RAC Flash update will start automatically, displaying status  information on the screen.

3. After the update has successfully completed,remove the  update diskette and reboot the system.

NOTE: This utility reprograms the RAC to preinstalled settings.  All user modified settings will be erased.

If you are upgrading a system and you want to save/restore any  modified RAC configurations, see the racadm getconfig/config commands in the “Dell Remote Access Controller Racadm User’s Guide” for instructions.

I installed it on my own PowerEdge 2650 Server and It worked great but sometimes if something goes wrong with the utility update then your system might goes blank and you won’t be able to see anything at all. No need to panic and just open the chassis of your server and pull out the ESM card and then plug it again. Your server will show you the previous corrupted stage and you can repair it again.Poweredge 2650 ESM error

Please leave your valuable comments about your experiences and if this article helped you please give it a thumbs up on stumble or facebook.

[download id=”1″]